Project Specs

Building

Concrete tilt-up construction, panelized hybrid roof structure, 753,230 SF footprint with provisions to construct 14,180 SF of mezzanine

Building Structure

10” square steel columns at 60’x 56’ with a hybrid metal truss roof system

Truck Courts

±190’ deep

Guard House

Services provided for future guardhouse with restroom at SE truck entry. Conduit for Power and data provided to NW truck entry

At-Grade Doors

Building shall include (4) 12’ wide x 15’ high, at-grade doors

Roof Insulation

Single ply, ESFR rated, white foil insulation under roof structure shall be part of TI budget

Electrical

480/277v, 3-phase electrical service with 4,000 amp capacity switchgear, 400 amp meter with house panel installed

Screening

Concrete screen wall to be provided at truck courts fronting Harley Knox Blvd. & Nandina Ave

Landscaping

Landscaping with automatic irrigation system provided

Site

36.4 Net Acres

Floors

7” thick, 4,000 PSI concrete warehouse floor. Finished to a FF 50/FL 35 standard

Trailer Parking

Approximately 130 truck trailer stalls

Elevations

Medium performance, “low E” glass at up-graded office entries

Sustainability

Designed to meet Title 24 Energy Standards & shall include the following:

  • Drought tolerant planting to reduce water usage
  • Energy efficient lighting

Offices

 2,402 SF spec office to be constructed.

Lighting

Warehouse lighting to meet Cal Green/Title 24 standards.  Auto parking & truck loading  courts to be designed with 1 fc of lighting provided utilizing LED wall and pole mounted fixtures

Dock Equipment

Bent plate “Z” guards provided at all truck & dock doors.  Additional dock equipment specifications to be determined by tenants

Clear Height

36’ clear below roof structure, measured behind loading dock bay column. All equipment, sprinklers, lights, and HVAC shall be mounted flush with the bottom of the roof structure or higher

Truck Docks

91 dock high doors (9’ x 10’ with 3’ HD rollers), 4 GL Doors (12’ x 15’)

Car Parking

 Approximately 410 auto parking stalls -exceed City minimum for car stalls

Fire Protection

ESFR fire protection meeting NFPA 13 spec in warehouse areas using a K-22 or K-25  ESFR sprinkler head. Office areas shall be protected by a “light hazard” .10 GPM/1500 SF system

Roofing

4-Ply Built-Up roofing system

Skylight

2% Curb mounted skylights provided.  Burglar bars shall be installed at all skylight  locations. Smoke hatch skylights shall also be provided at locations required by code

Warehouse HVAC

1/2 air change per hour to be provided, with the capacity to expand to 2 air changes

Steel Bollards

6” Diameter concrete filled steel bollards to be provided at interior power panels, sprinkler risers, pad mounted equipment, gas risers and exterior fire hydrants. 8”  Diameter concrete filled steel bollards to be provided at exterior locations

DOWNLOAD SPECS PDF

DOWNLOAD  BROCHURE

© CBRE, Inc. This information has been obtained from sources believed reliable. We have not verified it and make no guarantee, warranty or representation about it. Any projections, opinions, assumptions or estimates used are for example only and do not represent the current or future performance of the property. You and your advisors should conduct a careful, independent investigation of the property to determine to your satisfaction the suitability of the property for your needs.